We proudly manufacture in Australia and understand that one shape, size, or reach does not fit all designs. When designing you should not be constrained to fit inside a box. This is why we can manufacture tapware to the sizing required for a customer's application.

Two key measurements with most made to order outlets are the Overall Reach and Overall Height. These are always Centre to Centre measurements for reach and outside diameter measurements for Overall Height.

If there is a very specific application please send through a sketch or drawing to our sales team to discuss further and have it quoted for manufacture.

Aerators for Outlets - What are the normal options?

We normally offer three options for the end of outlets.

Flared Aerator Floline (Inline) Aerator Heritage Ring Nose (Not Aerated)
Flared Aerator Floline (Inline) Aerator Heritage Ring Nose (Not Aerated)

Key Notes Regarding Custom Outlet Sizing

 •   Gooseneck outlets' diameters (measurement reference A) are recommended below. They are somewhat limited to these size intervals due to the manufacturing method used, however the height (measurement reference B) is variable.

 •   Upswept outlets' bends and heights (measurement references A and B) are variable.

 •   Larger diameter measurements are nominal due to the nature of brass tubing. On larger outlets the actual reach may be +/- 10mm.

 •   For further information on these and other outlet shapes please refer to this FAQ page: Made to Measure Tapware & Accessories.


Roulette Hob Gooseneck Outlet  //  
Diagram # HOB-MTO-1
Roulette Hob Gooseneck Outlet - Diagram HOB-MTO-1
  Reach Height
  A A1 B B1 B2 B3
  Centre of Base
to
Centre of Tube
Base
Diameter
Overall
Height
Base
Height
Swivel Joint to Top of Tube Base to
Under Aerator
Standard Sink (Swivel) 215 55 250 45 205 110
Standard Basin (Fixed) 110 55 125 45 80 50
Standard Basin (Swivel) 110 55 150 45 105 70
Made to Order 130 55 175 45 130 80
(Default is Swivel) 160 55 210 45 165 100
  250 55 315 45 270 165
  315 55 355 45 310 185
  All measurements are in MM.

Roulette Hob Upswept Outlet  //  
Diagram # HOB-MTO-2
Roulette Hob Upswept Outlet - Diagram HOB-MTO-2
  Reach Height
  A A1 B B1 B2 B3
  Centre of Base
to
Centre of Tube
Base
Diameter
Overall
Height
Base
Height
Swivel Joint to Top of Tube Base to
Under Aerator
Standard Sink (Swivel) 200 55 200 45 155 135
Standard Basin (Swivel) 150 55 200 45 155 135
Made to Order 250 55 200 45 155 135
(Default is Swivel) 300 55 200 45 155 135
  All measurements are in MM.

Heritage Hob Gooseneck Outlet  //  
Diagram # HOB-MTO-3
Heritage Hob Gooseneck Outlet - Diagram HOB-MTO-3
  Reach Height
  A A1 B B1 B2 B3
  Centre of Base
to
Centre of Tube
Base
Diameter
Overall
Height
Base
Height
Swivel Joint to Top of Tube Base to
Under Aerator
Standard Sink (Swivel) 215 50 260 55 205 110
Standard Basin (Fixed) 110 50 125 55 70 50
Standard Basin (Swivel) 110 50 150 55 95 70
Made to Order 130 50 185 55 130 85
(Default is Swivel) 160 50 220 55 165 110
  250 50 325 55 270 175
  315 50 365 55 310 190
  All measurements are in MM.

Heritage Hob Upswept Outlet  //  
Diagram # HOB-MTO-4
Heritage Hob Upswept Outlet - Diagram HOB-MTO-4
  Reach Height
  A A1 B B1 B2 B3
  Centre of Base
to
Centre of Tube
Base
Diameter
Overall
Height
Base
Height
Swivel Joint to Top of Tube Base to
Under Aerator
Standard Sink (Swivel) 200 50 200 55 145 135
Standard Basin (Swivel) 150 50 200 55 145 135
Made to Order 250 50 200 55 145 135
(Default is Swivel) 300 50 200 55 145 135
  All measurements are in MM.

Roulette Wall Gooseneck Outlet  //  
Diagram # WALL-MTO-1
Roulette Wall Gooseneck Outlet - Diagram WALL-MTO-1
  Reach Height
  A A1 A2 B B1 B2 B3
  Wall to
Centre of
Aerator
Base to
Centre of
Swivel
Tube Only
Centre to Centre
Overall
Height from
Wall Centre
Centre of Base
to Top of
Swivel Joint
Swivel Joint
to Top of Tube
Centre of Base to
Under Aerator
Standard 270 55 215 240 35 205 100
Made to Order 165 55 110 135 35 100 55
  185 55 130 165 35 130 65
  215 55 160 200 35 165 80
  305 55 250 305 35 270 155
  370 55 315 345 35 310 175
  All measurements are in MM.
Wall base diameter is 65mm.

Roulette Wall Upswept Outlet  //  
Diagram # WALL-MTO-2
Roulette Wall Upswept Outlet - Diagram WALL-MTO-2
  Reach Height
  A A1 A2 B B1 B2 B3
  Wall to
Centre of
Aerator
Base to
Centre of
Swivel
Tube Only
Centre to Centre
Overall
Height from
Wall Centre
Centre of Base
to Top of
Swivel Joint
Swivel Joint
to Top of Tube
Centre of Base to
Under Aerator
Standard 255 55 200 180 35 145 115
Made to Order 195 55 140 180 35 145 115
  205 55 150 180 35 145 115
  235 55 180 180 35 145 115
  310 55 255 180 35 145 115
  360 55 305 180 35 145 115
  All measurements are in MM.
Wall base diameter is 65mm.

Heritage Wall Gooseneck Outlet  //  
Diagram # WALL-MTO-3
Heritage Wall Gooseneck Outlet - Diagram WALL-MTO-3
  Reach Height
  A A1 A2 B B1 B2 B3
  Wall to
Centre of
Aerator
Base to
Centre of
Swivel
Tube Only
Centre to Centre
Overall
Height from
Wall Centre
Centre of Base
to Top of
Swivel Joint
Swivel Joint
to Top of Tube
Centre of Base to
Under Aerator
Standard 280 65 215 240 35 205 100
Made to Order 175 65 110 135 35 100 55
  195 65 130 165 35 130 65
  225 65 160 200 35 165 80
  315 65 250 305 35 270 155
  380 65 315 345 35 310 175
  All measurements are in MM.
Wall base diameter is 50mm.

Heritage Wall Upswept Outlet  //  
Diagram # WALL-MTO-4
Heritage Wall Upswept Outlet - Diagram WALL-MTO-4
  Reach Height
  A A1 A2 B B1 B2 B3
  Wall to
Centre of
Aerator
Base to
Centre of
Swivel
Tube Only
Centre to Centre
Overall
Height from
Wall Centre
Centre of Base
to Top of
Swivel Joint
Swivel Joint
to Top of Tube
Centre of Base to
Under Aerator
Standard 265 65 200 180 35 145 115
Made to Order 205 65 140 180 35 145 115
  215 65 150 180 35 145 115
  245 65 180 180 35 145 115
  320 65 255 180 35 145 115
  370 65 305 180 35 145 115
  All measurements are in MM.
Wall base diameter is 50mm.