Outlet Reference Diagrams
We proudly manufacture in Australia and understand that one shape, size, or reach does not fit all designs. When designing you should not be constrained to fit inside a box. This is why we can manufacture tapware to the sizing required for a customer's application.
Two key measurements with most made to order outlets are the Overall Reach and Overall Height. These are always Centre to Centre measurements for reach and outside diameter measurements for Overall Height.
If there is a very specific application please send through a sketch or drawing to our sales team to discuss further and have it quoted for manufacture.
Aerators for Outlets - What are the normal options?
We normally offer three options for the end of outlets.
Flared Aerator | Floline (Inline) Aerator | Heritage Ring Nose (Not Aerated) |
Key Notes Regarding Custom Outlet Sizing
• |
Gooseneck outlets' diameters (measurement reference A) are recommended below. They are somewhat limited to these size intervals due to the manufacturing method used, however the height (measurement reference B) is variable. |
• |
Upswept outlets' bends and heights (measurement references A and B) are variable. |
• |
Larger diameter measurements are nominal due to the nature of brass tubing. On larger outlets the actual reach may be +/- 10mm. |
• |
For further information on these and other outlet shapes please refer to this FAQ page: Made to Measure Tapware & Accessories. |
Roulette Hob Gooseneck Outlet //
Diagram # HOB-MTO-1
Diagram # HOB-MTO-1
Reach | Height | |||||
A | A1 | B | B1 | B2 | B3 | |
Centre of Base to Centre of Tube |
Base Diameter |
Overall Height |
Base Height |
Swivel Joint to Top of Tube | Base to Under Aerator |
|
Standard Sink (Swivel) | 215 | 55 | 250 | 45 | 205 | 110 |
Standard Basin (Fixed) | 110 | 55 | 125 | 45 | 80 | 50 |
Standard Basin (Swivel) | 110 | 55 | 150 | 45 | 105 | 70 |
Made to Order | 130 | 55 | 175 | 45 | 130 | 80 |
(Default is Swivel) | 160 | 55 | 210 | 45 | 165 | 100 |
250 | 55 | 315 | 45 | 270 | 165 | |
315 | 55 | 355 | 45 | 310 | 185 | |
All measurements are in MM. |
Roulette Hob Upswept Outlet //
Diagram # HOB-MTO-2
Diagram # HOB-MTO-2
Reach | Height | |||||
A | A1 | B | B1 | B2 | B3 | |
Centre of Base to Centre of Tube |
Base Diameter |
Overall Height |
Base Height |
Swivel Joint to Top of Tube | Base to Under Aerator |
|
Standard Sink (Swivel) | 200 | 55 | 200 | 45 | 155 | 135 |
Standard Basin (Swivel) | 150 | 55 | 200 | 45 | 155 | 135 |
Made to Order | 250 | 55 | 200 | 45 | 155 | 135 |
(Default is Swivel) | 300 | 55 | 200 | 45 | 155 | 135 |
All measurements are in MM. |
Heritage Hob Gooseneck Outlet //
Diagram # HOB-MTO-3
Diagram # HOB-MTO-3
Reach | Height | |||||
A | A1 | B | B1 | B2 | B3 | |
Centre of Base to Centre of Tube |
Base Diameter |
Overall Height |
Base Height |
Swivel Joint to Top of Tube | Base to Under Aerator |
|
Standard Sink (Swivel) | 215 | 50 | 260 | 55 | 205 | 110 |
Standard Basin (Fixed) | 110 | 50 | 125 | 55 | 70 | 50 |
Standard Basin (Swivel) | 110 | 50 | 150 | 55 | 95 | 70 |
Made to Order | 130 | 50 | 185 | 55 | 130 | 85 |
(Default is Swivel) | 160 | 50 | 220 | 55 | 165 | 110 |
250 | 50 | 325 | 55 | 270 | 175 | |
315 | 50 | 365 | 55 | 310 | 190 | |
All measurements are in MM. |
Heritage Hob Upswept Outlet //
Diagram # HOB-MTO-4
Diagram # HOB-MTO-4
Reach | Height | |||||
A | A1 | B | B1 | B2 | B3 | |
Centre of Base to Centre of Tube |
Base Diameter |
Overall Height |
Base Height |
Swivel Joint to Top of Tube | Base to Under Aerator |
|
Standard Sink (Swivel) | 200 | 50 | 200 | 55 | 145 | 135 |
Standard Basin (Swivel) | 150 | 50 | 200 | 55 | 145 | 135 |
Made to Order | 250 | 50 | 200 | 55 | 145 | 135 |
(Default is Swivel) | 300 | 50 | 200 | 55 | 145 | 135 |
All measurements are in MM. |
Roulette Wall Gooseneck Outlet //
Diagram # WALL-MTO-1
Diagram # WALL-MTO-1
Reach | Height | ||||||
A | A1 | A2 | B | B1 | B2 | B3 | |
Wall to Centre of Aerator |
Base to Centre of Swivel |
Tube Only Centre to Centre |
Overall Height from Wall Centre |
Centre of Base to Top of Swivel Joint |
Swivel Joint to Top of Tube |
Centre of Base to Under Aerator |
|
Standard | 270 | 55 | 215 | 240 | 35 | 205 | 100 |
Made to Order | 165 | 55 | 110 | 135 | 35 | 100 | 55 |
185 | 55 | 130 | 165 | 35 | 130 | 65 | |
215 | 55 | 160 | 200 | 35 | 165 | 80 | |
305 | 55 | 250 | 305 | 35 | 270 | 155 | |
370 | 55 | 315 | 345 | 35 | 310 | 175 | |
All measurements are in MM. Wall base diameter is 65mm. |
Roulette Wall Upswept Outlet //
Diagram # WALL-MTO-2
Diagram # WALL-MTO-2
Reach | Height | ||||||
A | A1 | A2 | B | B1 | B2 | B3 | |
Wall to Centre of Aerator |
Base to Centre of Swivel |
Tube Only Centre to Centre |
Overall Height from Wall Centre |
Centre of Base to Top of Swivel Joint |
Swivel Joint to Top of Tube |
Centre of Base to Under Aerator |
|
Standard | 255 | 55 | 200 | 180 | 35 | 145 | 115 |
Made to Order | 195 | 55 | 140 | 180 | 35 | 145 | 115 |
205 | 55 | 150 | 180 | 35 | 145 | 115 | |
235 | 55 | 180 | 180 | 35 | 145 | 115 | |
310 | 55 | 255 | 180 | 35 | 145 | 115 | |
360 | 55 | 305 | 180 | 35 | 145 | 115 | |
All measurements are in MM. Wall base diameter is 65mm. |
Heritage Wall Gooseneck Outlet //
Diagram # WALL-MTO-3
Diagram # WALL-MTO-3
Reach | Height | ||||||
A | A1 | A2 | B | B1 | B2 | B3 | |
Wall to Centre of Aerator |
Base to Centre of Swivel |
Tube Only Centre to Centre |
Overall Height from Wall Centre |
Centre of Base to Top of Swivel Joint |
Swivel Joint to Top of Tube |
Centre of Base to Under Aerator |
|
Standard | 280 | 65 | 215 | 240 | 35 | 205 | 100 |
Made to Order | 175 | 65 | 110 | 135 | 35 | 100 | 55 |
195 | 65 | 130 | 165 | 35 | 130 | 65 | |
225 | 65 | 160 | 200 | 35 | 165 | 80 | |
315 | 65 | 250 | 305 | 35 | 270 | 155 | |
380 | 65 | 315 | 345 | 35 | 310 | 175 | |
All measurements are in MM. Wall base diameter is 50mm. |
Heritage Wall Upswept Outlet //
Diagram # WALL-MTO-4
Diagram # WALL-MTO-4
Reach | Height | ||||||
A | A1 | A2 | B | B1 | B2 | B3 | |
Wall to Centre of Aerator |
Base to Centre of Swivel |
Tube Only Centre to Centre |
Overall Height from Wall Centre |
Centre of Base to Top of Swivel Joint |
Swivel Joint to Top of Tube |
Centre of Base to Under Aerator |
|
Standard | 265 | 65 | 200 | 180 | 35 | 145 | 115 |
Made to Order | 205 | 65 | 140 | 180 | 35 | 145 | 115 |
215 | 65 | 150 | 180 | 35 | 145 | 115 | |
245 | 65 | 180 | 180 | 35 | 145 | 115 | |
320 | 65 | 255 | 180 | 35 | 145 | 115 | |
370 | 65 | 305 | 180 | 35 | 145 | 115 | |
All measurements are in MM. Wall base diameter is 50mm. |